Designed to measure the Direct Normal Irradiance (DNI) without implementing a sun tracking system, the MS-90 DNI Sensor is an accurate solution for many applications. Featuring a rotating mirror that reflects the sunbeam onto a thermal detector, it can be used in combination with any pyranometer to measure the Global Horizontal Irradiance and the DNI to calculate the Diffuse Horizontal Irradiance (DHI).
This sensor uses a pulsed analogue output that can work with dataloggers with a pulsed analogue peak hold or input function – with the analogue pulse (0-5V) in proportion with the DNI.
ASK A QUICK QUESTIONSpecifications | MS-90 |
ISO 9060:1990 | - |
Output | 0-5V (Pulse) |
Temperature response -20°C to 40°C | +/- 5 % |
Non-linearity | +/- 2.5 % |
Operating temperature range | -20 - 45 °C |
Wavelength range | 300 - 2500 nm |
Power supply | 10.5 - 12.5 VDC |
Dimensions mm | 350 (W) x 250 (L) x 200 (H) (Incl. optional base plate) |
Weight | 2.5 kg |
Ingress protection IP | 67 |
Cable length | 10 m |
Geographic application | Lattitude (-58º to 58º ) / Longitude (0º to 360º) |
Power consumption | < 5 W |
Cable length | 20 / 30 / 50 m |
Base plate | 350 x 250 / leveling feet mm |
Power supply | 100 to 240 VAC / 12VDC / 200 x 140 x 80mm / 2.5 kg |