The MP-160 I-V tracer is the best solution for testing individual solar cell or module characteristics in combination with a solar simulator or natural sun light. It can be found in factory quality control applications or long term performance assessment studies of modules exposed to natural conditions outdoors. The cell or module performance characteristics are determined by changing the electrical load during the I-V sweep. The radiant energy on the module energy can be measured simultaneously with the Voltage and current measurements in order to calculate to STC or equivalent standards.
For outdoor evaluation of PV modules under natural sun light and environmental conditions the MP-160 offers a high level of flexibility to test several modules at the same time. During long term exposure tests, automatic measurement can be scheduled for continuous data retrieval of the measurable modules parameters. By using the module selectors up to 48 modules can be connected to the MP-160 to sequentially measure each individual I-V curve. Similarly individual temperature measurements are performed with the T-type thermocouple selector. If modules are mounted with different tilt angles, the 5 channel pyranometer selector can be used to measure the total radiation in plane with the module.
Specifications | MP-160 |
Measuring range | 300V, 30V, 3V / 10A, 3A, 0.3A, 0.03A |
Rated power of PV device | Max.300 W |
A/D converter | 16 Bit |
The number of data points per sweep | Max. 256 points |
Communication speed | 38400 bps (or 9600 bps) |
Size | 370 W x 350 D x 133 H (mm) |
Weight | 9 kg |
Power supply | AC 100 to 240 V, 50/60Hz, max. 200VA |